AAC/CellSMART Service Data Module

Product Image
ATM ASE for Visual UpTime
General

Monitors traffic on user-specified ports and VCs

Sends SLM messages of the configured size every 15 minutes to Visual UpTime

Sends SNMP traps about AAC events to Visual UpTime

Field replaceable (not hot-swappable)

Provides data for Visual UpTime reports

Burst advisor for channel and end-to-end VC

ATM Quality of Service

Network usage profile

Most active channels and VCs and circuits in channel

Most underutilized and overutilized channels and VCs

Utilization and throughput for channel and VC, by Class of Service and AAL type for channel

Usage counts for channel and single-ended and end-to-end VC

Most congested VCs

Service level verification statistics for end-to-end VC, and service level report

Availability, frame delivery ratio, and round-trip delay for VC

Top problem physical lines and access channels for ATM

Access line performance

Provides data for Visual UpTime toolsets

Event Processor

Troubleshooting

Planning and Reporting

Provides data for Visual UpTime Troubleshooting views

Real-time, 2 hours, and 2 days

Access line summary and statistics views

Access channel summary, statistics, burst, burst advisor, circuit details, and AAL utilization

VC summary, statistics, burst, burst advisor, congestion, service advisor, and verify connectivity

Provides events to the Visual UpTime Event Processor

Link layer and circuit changes

Physical layer state changes

SNMP authentication failure

Cold starst and warm starts

FPING Termination for ServicePoint and DataSMART
Far-end statistics

Allows ServicePoint and DataSMART devices at the far end of monitored circuits to collect SLA statistics

Round-trip delay

End-to-end delay

Data delivery ratio

Frame delivery ratio

Frame Dropped - Received and Transmitted

FPING response

Responds to FPING messages from other Kentrox equipment, such as ServicePoint SDUs and DataSMART Frame monitoring DSUs

Traffic Monitoring Capabilities
Criteria for networks-side monitoring

The SDM's network-side monitoring can be done only for ports and circuits that meet all of the following criteria

Network-side port uses the ATM UNI protocol and any PLM other than the J2 PLM

Circuit is on a port that has network-side monitoring enabled

Circuit is cross-connected to another circuit that is on a cell port, a VBR packet port configured for Frame Relay, or the ISC port

Circuit's cross-connect is configured to be a bi-directional, unicast BCC that uses AAL5 adaption. The VCC may be a part of a VPL

The SDM's FPING termination feature must also meet the above criteria, except that the network-side port may also use the Frame Relay protocol.

Other

Monitors up to 512 VCs

Monitors VCs with a maximum aggregate rate equivalent to bi-directional DS3 (44.736 Mbps) with 200 byte packets.

ACO Button
ACO Button

The Alarm Cut Off button deactivates the audible alarm relay contacts.

Backup Configuration Memory
Memory

1 MB non-volatile configuration memory controlled by ISC.